< Home

loss-measure enable

Function

The loss-measure enable command enables statistics collection based on the time range for a measurement instance on a DCP.

The undo loss-measure enable command disables statistics collection for a measurement instance on a DCP.

By default, statistics collection based on the time range is disabled for a measurement instance on a DCP.

Format

loss-measure enable [ mid-point ] [ time-range time-range ]

undo loss-measure enable [ [ mid-point ] time-range [ time-range ] ]

Parameters

Parameter Description Value
mid-point

Enables on-demand packet loss measurement for mid-points.

If this parameter is configured, on-demand packet loss measurement is enabled for all mid-points. If this parameter is not configured, on-demand packet loss measurement is enabled for all measurement points.

NOTE:

The mid-point is only applied to hop-by-hop measurement.

-
time-range time-range Specifies the time range for statistics collection. The value is 5, 10, 15, or 30, in minutes. The default value is 10 minutes.

Views

IPFPM-DCP instance view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

The IP FPM performance statistics serve as a reliable reference for assessing IP network performance and therefore are useful for fault diagnosis and service statistics. To monitor on-demand packet loss performance in a specified period or diagnose network faults and locate faulty nodes when network performance deteriorates, run the loss-measure enable command.

Prerequisites

An IP FPM model has been established, including configuring a DCP and MCP, binding a TLP to a physical interface, and creating a target flow and IP FPM instance.

Precautions

This command is not recorded in the configuration file after being executed.

After device restart, statistics collection based on the time range becomes invalid, and needs to be reconfigured.

Statistics collection based on the time range and continual statistics collection cannot be enabled simultaneously.

Example

# Enable statistics collection based on the time range for a measurement instance on a DCP.

<HUAWEI> system-view
[HUAWEI] nqa ipfpm dcp
[HUAWEI-nqa-ipfpm-dcp] instance 1
[HUAWEI-nqa-ipfpm-dcp-instance-1] loss-measure enable time-range 30
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.