< Home

instance (IPFPM-MCP view)

Function

The instance command creates an IPFPM-MCP instance and displays the IPFPM-MCP instance view, or directly displays the view of an existing IPFPM-MCP instance.

The undo instance command deletes an IPFPM-MCP instance.

By default, no IPFPM-MCP instance is created on the MCP.

Format

instance instance-id

undo instance instance-id

Parameters

Parameter Description Value
instance-id Specifies the ID of an IPFPM-MCP instance. The value is an integer that ranges from 1 to 8355838.

Views

IPFPM-MCP view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

The DCP collects statistics data based on measurement instances. Each measurement instance consists of the target flow, TLP, and measurement interval. The MCP reports measurement results based on measurement instances. The MCP summarizes and analyzes statistics data of the same measurement instance on all DCPs, and reports measurement results of target flows.

Prerequisites

Global MCP has been enabled using the nqa ipfpm mcp command.

Precautions

To measure packet loss for a specified service flow, create the same measurement instance on the MCP and DCP.

Example

# Create IPFPM-MCP instance 1.

<HUAWEI> system-view
[HUAWEI] nqa ipfpm mcp
[HUAWEI-nqa-ipfpm-mcp] instance 1
Copyright © Huawei Technologies Co., Ltd.