The monitor output enable command configures the initial status of the monitoring function on an output line connected to a monitoring interface to enabled.
The undo monitor output enable command configures the initial status of the monitoring function on an output line connected to a monitoring interface to disabled.
By default, the initial status of the monitoring function on an output line is not configured.
Only the S5735-S-I supports this command.
Parameter | Description | Value |
---|---|---|
line-id |
Specifies the ID of an output line. |
The value is 1. |
slot slot-id |
Specifies the slot ID. |
The value must be set according to the device configuration. |
After the monitor output enable command is run, the initial status of the monitoring function on an output line (DOUT status for short) is configured to enabled. If the maintenance compartment door is opened, the DOUT status changes to disabled. If the maintenance compartment door is closed, the DOUT status changes to enabled. You can monitor whether the maintenance compartment door is opened based on the DOUT status.
Similarly, after the undo monitor output enable command is run, the initial DOUT status is configured to disabled. If the maintenance compartment door is opened, the DOUT status changes to enabled. If the maintenance compartment door is closed, the DOUT status changes to disabled.