remote-mep

Function

The remote-mep command configures an RMEP in an MA.

The undo remote-mep command deletes an RMEP from an MA.

Format

remote-mep mep-id mep-id [ mac mac-address ]

undo remote-mep mep-id mep-id

Parameters

Parameter Description Value
mep-id mep-id Specifies the ID of an RMEP. The value is an integer that ranges from 1 to 8191.
mac mac-address Specifies the MAC address of an RMEP. The value is in H-H-H format. An H is a hexadecimal number of 1 to 4 digits.

Views

MA view

Default Level

2: Configuration level

Usage Guidelines

Usage Scenario

To configure an RMEP, use this command.

Precautions

To detect CFM connectivity faults between a device and an RMEP in an MA, complete the following tasks:

  • Run the remote-mep command to configure an RMEP in an MA.

  • Run the remote-mep ccm-receive enable command to enable the MEP to receive CCMs from the RMEP.

To modify the bridge MAC address of the RMEP, you must delete the RMEP from an MA and then reconfigure the RMEP.

The RMEP ID must be different from the MEP ID configured on a local interface.

  • If multiple MEPs exist in an MA, the configured RMEP corresponds to multiple MEPs.

  • If one MEP exists in an MA, one or more configured RMEPs correspond to one MEP.

Example

# Configure RMEP 10 in ma1 on the device with the bridge MAC address of 0001-0300-0204.

<HUAWEI> system-view
[HUAWEI] cfm enable
[HUAWEI] cfm md md1
[HUAWEI-md-md1] ma ma1
[HUAWEI-md-md1-ma-ma1] remote-mep mep-id 10 mac 0001-0300-0204