reset stack-port configuration

Function

The reset stack-port configuration command clears the service port stack configuration.

Only the S5720-EI, S5730-SI, and S5730S-EI support this command.

Format

reset stack-port configuration [ slot slot-id ]

Parameters

Parameter

Description

Value

slot slot-id

Specifies a stack ID.

The value is an integer that ranges from 0 to 8.

Views

System view

Default Level

3: Management level

Usage Guidelines

Usage Scenario

  • When the current stack connection mode is service port connection, you must run the reset stack-port configuration command to clear the existing service port stack configuration before changing the stack connection mode to stack card connection. After the configuration is cleared, restart the stack and then the stack card connection mode takes effect.
  • If the current stack connection mode is stack card connection, you can run the reset stack-port configuration command to clear the service port stack configuration if such configuration already exists. You can run the display stack configuration command to check the existing service port stack configuration.

Precautions

  • In service port connection mode, after clearing the service port stack configuration of a member switch, restart the switch to make the configuration take effect. If you perform the service port stack configuration on the member switch before restarting, the service port stack configuration on the member switch is not cleared.
  • When the stack is changed from service port connection to stack card connection, remove the cables connected to service ports to prevent potential loops.
  • On the S5730-SI or SS5730S-EI, after dedicated stack cables are installed, you need to run the save stack configuration or save command to save the automatically generated stack configuration to the flash memory and then run the reset stack-port configuration command to clear the service port stack configuration.

Example

# Clear the service port stack configuration.

<HUAWEI> system-view
[HUAWEI] reset stack-port configuration
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.