The sta-load-balance dynamic probe-report interval command sets the interval for reporting Probe frames.
The undo sta-load-balance dynamic probe-report interval command restores the default interval for reporting Probe frames.
By default, Probe frames are reported at an interval of 120 seconds.
sta-load-balance dynamic probe-report interval interval
undo sta-load-balance dynamic probe-report interval
Parameter |
Description |
Value |
---|---|---|
interval |
Specifies the interval for reporting Probe frames. |
The value is an integer that ranges from 30 to 300, in seconds. |
Usage Scenario
After an AP receives information about neighboring APs of STAs, it reports the information to the AC for determining the target APs to which the STAs will roam. You can run the sta-load-balance dynamic probe-report interval command to set the interval at which the AP reports information about neighboring APs of the STAs.
Precautions
You are advised to retain the default value. If the device has high performance pressure, you can set a longer interval.