Try to build session, but the session number in the IO board with interface has reached the limit, the new session binding with interface can not be created. (ConfigurationName=[ConfigurationName], InterfaceName=[InterfaceName], SessionLimitPerBoard=[SessionLimitPerBoard])
The number of BFD sessions established on the board where the bound interface resides has reached the PAF upper limit, and no more BFD session can be bound to the interface.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
BfdSessReachLimitBindIf |
Trap OID |
1.3.6.1.4.1.2011.5.25.38.3.4 |
MIB |
HUAWEI-BFD-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
ConfigurationName |
Indicates the name of the BFD session. |
InterfaceName |
Indicates the name of the interface bound to the BFD session. |
SessionLimitPerBoard |
Maximum number of sessions per slot. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.38.2.2.1.7 |
hwBfdSessConfBindIfName |
hwBfdSessConfName |
1.3.6.1.4.1.2011.5.25.38.1.4 |
hwBfdSessInterfaceLimitNumber |
- |
1. Run the display bfd statistics command to check whether the number of BFD_IO_SESSION_NUM in the slot reaches the upper limit.
2. After the BFD sessions bound to the interface is deleted, the BFD sessions whose configurations are committed are automatically established. In this case, go to Step 4.
3. Collect log and configuration information, and contact technical support personnel.
4. End.