The master main control board is reset after the address pool is isolated. (PoolName=[PoolName],PoolIndex=[PoolIndex])
The master main control board was restarted after the address pool was isolated.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
hwIPPoolIsolatedCauseMainboardReset |
Trap OID |
1.3.6.1.4.1.2011.6.8.2.2.0.48 |
MIB |
HUAWEI-IPPOOL-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
PoolName |
Name of an address pool. |
PoolIndex |
Index of an address pool. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.6.8.1.1.1.2 |
hwIPPoolName |
hwIPPoolIndex |
1. Wait for the master main control board to restart.
2. Check whether the address pool is isolated again.
3. Collect trap, log, and configuration information, and contact technical support personnel.
4. End.