BRASAM_1.3.6.1.4.1.2011.6.8.2.2.0.48 hwIPPoolIsolatedCauseMainboardReset

Trap Buffer Description

The master main control board is reset after the address pool is isolated. (PoolName=[PoolName],PoolIndex=[PoolIndex])

The master main control board was restarted after the address pool was isolated.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwIPPoolIsolatedCauseMainboardReset

Trap OID

1.3.6.1.4.1.2011.6.8.2.2.0.48

MIB

HUAWEI-IPPOOL-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

PoolName

Name of an address pool.

PoolIndex

Index of an address pool.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.6.8.1.1.1.2

hwIPPoolName

hwIPPoolIndex

Impact on the System

The system is not affected.

Possible Causes

User login failed, and the address pool had been isolated for 20 times.

Procedure

1. Wait for the master main control board to restart.

2. Check whether the address pool is isolated again.

  • If so, go to Step 3.
  • If not, go to Step 4.

3. Collect trap, log, and configuration information, and contact technical support personnel.

4. End.