CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.13 hwClockSourceFreqCheckResume

Trap Buffer Description

The check of frequence normal notification. (hwClockSrcCfgChassisIndex=[hwClockSrcCfgChassisIndex], hwClockSrcCfgSourceTypeIndex=[hwClockSrcCfgSourceTypeIndex], hwClockSrcCfgSourceIndex=[hwClockSrcCfgSourceIndex], hwClockChassisId=[hwClockChassisId], hwClockSrcCfgFreqCheckResult=[hwClockSrcCfgFreqCheckResult], hwClockSrcCfgSourceDescr=[hwClockSrcCfgSourceDescr])

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwClockSourceFreqCheck

Trap OID

1.3.6.1.4.1.2011.5.25.186.1.8.13

MIB

HUAWEI-CLOCK-MIB

Alarm ID

0x09af0003

Alarm Name

hwClockSourceFreqCheck

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.5 hwClockSourceFreqCheck

Trap Buffer Parameters

Parameter Description

hwClockSrcCfgChassisIndex

Indicates the index of the chassis where the non-PTP clock source is located. In the case of a single chassis, the index is 1. For a chassis where a PTP clock source is located, the index is invalid.

hwClockSrcCfgSourceTypeIndex

Index of the clock source type. values:

bits(1).

ptp(2).

interface(3).

cesacr(4).

hwClockSrcCfgSourceIndex

Index of the clock source.

hwClockChassisId

Chassis id.

hwClockSrcCfgFreqCheckResult

Result of the check of frequency, values:

abnormal(0).

normal(1).

hwClockSrcCfgSourceDescr

The description of clock source.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.186.1.7.4

hwClockChassisId

-

1.3.6.1.4.1.2011.5.25.186.1.11.1.4

hwClockSrcCfgSourceDescr

hwClockSrcCfgChassisIndex

hwClockSrcCfgSourceTypeIndex

hwClockSrcCfgSourceIndex

1.3.6.1.4.1.2011.5.25.186.1.11.1.12

hwClockSrcCfgFreqCheckResult

hwClockSrcCfgChassisIndex

hwClockSrcCfgSourceTypeIndex

hwClockSrcCfgSourceIndex

Impact on the System

The system is not affected.

Possible Causes

The frequency offset value of the tracking source changes from above 9.2 ppm to below 8.7 ppm.

Procedure

This alarm is informational only, and no action is required.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >