CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.7 hwClockNotInLockedMode

Trap Buffer Description

The work mode of system clock source out trace. (hwClockAttributeChassisIndex=[hwClockAttributeChassisIndex], hwClockChassisId=[hwClockChassisId], hwClockAttributeSysClkLockMode=[hwClockAttributeSysClkLockMode])

The clock source synchronization failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwClockNotInLockedMode

Trap OID

1.3.6.1.4.1.2011.5.25.186.1.8.7

MIB

HUAWEI-CLOCK-MIB

Alarm ID

0x09af0005

Alarm Name

hwClockNotInLockedMode

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.8 hwClockInLockedMode

Trap Buffer Parameters

Parameter Description

hwClockAttributeChassisIndex

Indicates the index of the chassis where the non-PTP clock source is located. In the case of a single chassis, the index is 1. For a chassis where a PTP clock source is located, the index is invalid.

hwClockChassisId

Chassis id of the clock source.

hwClockAttributeSysClkLockMode

Lock mode of system clock.Inter-chassis synchronization type. values:

freeRun(0).

fastLock(1).

lock(2).

hold(3).

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.186.1.7.4

hwClockChassisId

-

1.3.6.1.4.1.2011.5.25.186.1.9.1.12

hwClockAttributeSysClkLockMode

hwClockAttributeChassisIndex

Impact on the System

The device cannot synchronize its clock with a device with better clock quality.

Possible Causes

Cause1: No external clock source could be traced.

Cause2: The external clock source was unqualified due to some defects such as frequency offset.

Cause3: The synchronization mode of the clock was forcibly set to free.

Procedure

1. Run the display clock config command to check whether the working mode of the clock is normal.

  • If so, go to step 2.
  • If not, go to step 4.

2. Run the display clock source command to check whether an available clock source is configured to be traced. For example, check whether the clock source is in a correct state, whether the user is configured with a priority, and whether the clock source is configured with a valid SSM level.

  • If so, go to step 5.
  • If not, go to step 3.

3. Configure the clock again. For details, see Clock Synchronization Configuration in Configuration Guide - Basic Configuration.

Run the clock run-mode normal command to configure the clock source to work in normal mode and check whether the configuration succeeds.

  • If so, go to step 2.
  • If not, go to step 5.

4. Collect the alarm, log, and configuration information, and contact Huawei technical support personnel.

5. End.