DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.5 hwEntityReset-66591

Trap Buffer Description

Physical entity reset. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=66591, BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntPhysicalContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Because of user operation or software exception, the entity has been reset, now it is ready.)

The physical entity reset because a part failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwEntityReset

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.1.5

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x08130094

Alarm Name

hwEntityReset

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.6 hwEntityResetDone-66591

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

Indicates the physical index.

BaseTrapProbableCause

Possible reason.

BaseTrapEventType

Indicates the possible cause of the trap.

EntityPhysicalIndex

Indicates the trap type.

EntPhysicalContainedIn

Indicates the parent index.

EntPhysicalName

Indicates the name of the entity such as a chassis.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.4

entPhysicalContainedIn

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.4

hwBaseTrapRelativeResource

-

1.3.6.1.4.1.2011.5.25.129.1.5

hwBaseTrapReasonDescr

-

Impact on the System

All single boards in the reset chassis will be reset, and all the business of the chassis will be affected.

Possible Causes

Because of user operation or software exception, the entity has been reset, now it is ready.

Procedure

1. The boards in the chassis will register automatically. Check if the board can work normally after registering automatically.

  • If so, go to Step 4.
  • If not, go to Step 2.

2. Pull out the unregistered boards and replace them with new boards. Then, check whether the trap is recovered.

  • If so, go to Step 4.
  • If not, go to Step 3.

3. Collect trap information, log information, and configuration information, and then contact technical support personnel.

4. End.