Physical entity reset. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=66591, BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntPhysicalContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Because of user operation or software exception, the entity has been reset, now it is ready.)
The physical entity reset because a part failed.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwEntityReset |
Trap OID |
1.3.6.1.4.1.2011.5.25.129.2.1.5 |
MIB |
HUAWEI-BASE-TRAP-MIB |
Alarm ID |
0x08130094 |
Alarm Name |
hwEntityReset |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.6 hwEntityResetDone-66591 |
Parameter | Description |
---|---|
BaseTrapSeverity |
Indicates the physical index. |
BaseTrapProbableCause |
Possible reason. |
BaseTrapEventType |
Indicates the possible cause of the trap. |
EntityPhysicalIndex |
Indicates the trap type. |
EntPhysicalContainedIn |
Indicates the parent index. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.1.1 |
hwBaseTrapSeverity |
- |
1.3.6.1.4.1.2011.5.25.129.1.2 |
hwBaseTrapProbableCause |
- |
1.3.6.1.4.1.2011.5.25.129.1.3 |
hwBaseTrapEventType |
- |
1.3.6.1.2.1.47.1.1.1.1.4 |
entPhysicalContainedIn |
entPhysicalIndex |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.129.1.4 |
hwBaseTrapRelativeResource |
- |
1.3.6.1.4.1.2011.5.25.129.1.5 |
hwBaseTrapReasonDescr |
- |
1. The boards in the chassis will register automatically. Check if the board can work normally after registering automatically.
2. Pull out the unregistered boards and replace them with new boards. Then, check whether the trap is recovered.
3. Collect trap information, log information, and configuration information, and then contact technical support personnel.
4. End.