Physical entity reset. (EntityPhysicalIndex=[ULONG],BaseTrapSeverity=4, BaseTrapProbableCause=66590, BaseTrapEventType=5, EntityPhysicalIndex=[ULONG], EntPhysicalContainedIn=[ULONG], EntPhysicalName=[STRING], RelativeResource=[STRING], ReasonDescription=Because of user operation or software exception, the entity has been resetted, now it is ready)
The physical entity reset because a part failed.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwEntityReset |
Trap OID |
1.3.6.1.4.1.2011.5.25.129.2.1.5 |
MIB |
HUAWEI-BASE-TRAP-MIB |
Alarm ID |
0x08130094 |
Alarm Name |
hwEntityReset |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.6 hwEntityResetDone-66590 |
Parameter | Description |
---|---|
BaseTrapSeverity |
Indicates the physical index. |
BaseTrapProbableCause |
Possible reason. |
BaseTrapEventType |
Indicates the possible cause of the trap. |
EntityPhysicalIndex |
Indicates the trap type. |
EntPhysicalContainedIn |
Indicates the parent index. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.1.1 |
hwBaseTrapSeverity |
- |
1.3.6.1.4.1.2011.5.25.129.1.2 |
hwBaseTrapProbableCause |
- |
1.3.6.1.4.1.2011.5.25.129.1.3 |
hwBaseTrapEventType |
- |
1.3.6.1.2.1.47.1.1.1.1.4 |
entPhysicalContainedIn |
entPhysicalIndex |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.129.1.4 |
hwBaseTrapRelativeResource |
- |
1.3.6.1.4.1.2011.5.25.129.1.5 |
hwBaseTrapReasonDescr |
- |
1. If an interface board is reset, all services on the interface board will be interrupted.
2. If the master MPU is reset, a master/slave MPU switchover will occur.
3. If the slave MPU is reset and it can work normally after registration. services are not affected.
4. If an SFU is reset, the SFU cannot exchange data.
1.Check whether the board registers after a reset.
2. Replace the board and then check whether the alarm is cleared after the board registers.
3. Collect trap, log, and configuration information, and contact technical support personnel.
4. End.