DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid-67593

Trap Buffer Description

Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67593], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Cause1:A power module failed.A fault occurred on the power module. Cause2:Internal communication failed for a power module. Communication between the power module and main processing unit in the same chassis failed.)

Physical entity failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwEntityInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.1.9

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x08130055

Alarm Name

hwEntityInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.10 hwEntityResume-67593

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.4

entPhysicalContainedIn

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.4

hwBaseTrapRelativeResource

-

1.3.6.1.4.1.2011.5.25.129.1.5

hwBaseTrapReasonDescr

-

Impact on the System

A power supply failure may lead to power supply insufficiency on the device, which affects services. This problem needs to be solved.

Possible Causes

Cause1:A power module failed.A fault occurred on the power module.

Cause2:Internal communication failed for a power module. Communication between the power module and main processing unit in the same chassis failed.

Procedure

1. Check whether the power module is connected properly and the power switch is off. If so, switch on the power. Check whether the input of the power module is normal. If not, install the power module properly. Then, check whether the alarm is cleared after the external input is complete.

  • If so, go to Step 5.
  • If not, go to Step 2.

2. Check whether the power module is inserted completely. Then, check whether the alarm is cleared after the power module is removed and inserted again.

  • If so, go to Step 5.
  • If not, go to Step 3.

3. Replace the power module and check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.

5. End.

Copyright © Huawei Technologies Co., Ltd.