Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67592], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The hardware of the fan was faulty.)
Physical entity failed.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwEntityInvalid |
Trap OID |
1.3.6.1.4.1.2011.5.25.129.2.1.9 |
MIB |
HUAWEI-BASE-TRAP-MIB |
Alarm ID |
0x08130055 |
Alarm Name |
hwEntityInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.129.1.1 |
hwBaseTrapSeverity |
- |
1.3.6.1.4.1.2011.5.25.129.1.2 |
hwBaseTrapProbableCause |
- |
1.3.6.1.4.1.2011.5.25.129.1.3 |
hwBaseTrapEventType |
- |
1.3.6.1.2.1.47.1.1.1.1.4 |
entPhysicalContainedIn |
entPhysicalIndex |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.129.1.4 |
hwBaseTrapRelativeResource |
- |
1.3.6.1.4.1.2011.5.25.129.1.5 |
hwBaseTrapReasonDescr |
- |
1. Check whether the fan frame is installed well. Remove and insert the fan frame to ensure that it is installed well. Run the display fan command to check the status of the fan. Then, check whether the fan works properly and the alarm is cleared.
2. Replace the fan and check whether the alarm is cleared.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.