DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid-68147

Trap Buffer Description

Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[68147], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The link-heartbeat detection packet was modified on the link.)

Physical entity failed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwEntityInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.1.9

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x08130055

Alarm Name

hwEntityInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.10 hwEntityResume-68147

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.4

entPhysicalContainedIn

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.4

hwBaseTrapRelativeResource

-

1.3.6.1.4.1.2011.5.25.129.1.5

hwBaseTrapReasonDescr

-

Impact on the System

The link-heartbeat linkage packet-modify enable command run in the slot view may lead to operations, such as interface shutdown, subcard resetting, and board resetting. After such operations are performed, if the alarm persists, a hardware fault occurs, which may cause packets to be modified. This problem needs to be solved immediately.

Possible Causes

The link-heartbeat detection packet was modified on the link.

Procedure

1. Run the power off slot slot-id and power on slot slot-id commands on the boards at both ends of the direct link. After the boards are registered, check whether the alarm is cleared.

  • If so, go to Step 4.
  • If not, go to Step 2.

2. Replace the board, and then check whether the alarm is cleared.

  • If so, go to Step 4.
  • If not, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.