DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.3 hwChassisFail-131350

Trap Buffer Description

The chassis failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131350, Reason=Device power is insufficient for user config power limit.

The chassis experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwChassisFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.1.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x081300b4

Alarm Name

hwChassisFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume-131350

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity, such as chassis.

ReasonDescription

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

The board may be powered off or the newly board may fail to be registered due to power insufficiency.

Possible Causes

The power supply would be abnormal because power limit was configured insufficiently.

Procedure

1. Confirm with the customer whether the specified power consumption limit can be reached.

  • If yes, go to Step 2.
  • If no, go to Step 3.

2. Increase the power consumption to make it reach the specified upper limit. Then, check whether the alarm can be cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 3.

3. Insert more PMs and make them work. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.

5. End.