The chassis failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131347, Reason=the number of pm on two plane is different.)
The chassis experienced a partial failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwChassisFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.1.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x081300b4 |
Alarm Name |
hwChassisFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume-131347 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the physical entity, such as chassis. |
ReasonDescription |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. Check whether the number of PMs on the two planes are consistent.
2. Install the same number of PMs on the two planes.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.