The chassis resumed from partial failure. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131352, Reason=The cable of LPU area is not stable.)
The chassis experienced a partial failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwChassisFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.1.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x081300b4 |
Alarm Name |
hwChassisFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume-131352 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the physical entity, such as chassis. |
ReasonDescription |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. Remove and then insert the faulty fan located in the LPU area.When the fan is registered, check whether the alarm is cleared.
2. Contact technical support personnel. and check whether the LPU area cable for the fan backplane is securely inserted.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.