DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.3 hwChassisFail-131351

Trap Buffer Description

The chassis resumed from partial failure. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131351, Reason=Power backplane cable is not stable.)

The chassis experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwChassisFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.1.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x081300b4

Alarm Name

hwChassisFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume-131351

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity, such as chassis.

ReasonDescription

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Power failure may cause device power supply is insufficient, which may cause the board is reset due to insufficient power supply, indirect impact on services, need to be processed immediately.

Possible Causes

Power backplane cable is not stable

Procedure

1. Run the slave switchover command to switchover ,and wait for a period of time,check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 3.
  • If the alarm persists, go to Step 2.

2. Contact technical support and check whether the power supply unit backplane cable is securely inserted.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.