The board temperature exceeded the upper alarm threshold. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=143618, Reason=The fan temperature was too high.)
The board or subcard temperature alarm.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwBrdTempAlarm |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.10.13 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x0813000d |
Alarm Name |
hwBrdTempAlarm |
Alarm Type |
environmentalAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.14 hwBrdTempResume-143618 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Indicates the description of the cause of the trap. |
EntPhysicalName |
Indicates the name of the physical entity, such as "SFU | LPU | MPU slot slotID". The entity name varies according to the board type, such as the SFU, LPU, and MPU. |
EntityThresholdType |
The abnormal type for temperature.The value can be:
|
EntityThresholdCritical |
The warning alarm threshold for warning alarm. |
EntityThresholdCurrent |
The current value that been measured. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.5.1.1 |
hwEntityThresholdType |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.5.1.5 |
hwEntityThresholdWarning |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.5.1.3 |
hwEntityThresholdCurrent |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1. Check if the filter screen of the fan module is clogged. If the filter screen is clogged, clean the filter screen.
2. Check the ambient temperature. If the ambient temperature is too high, reduce the temperature to a normal level.
3. Check if the fan module is faulty. If there is a fault on the fan module, rectify the fault first.
4. If the ambient temperature is normal but the alarm is still reported, the possible cause is that the module temperature is too high. In this case, collect the information about alarms, logs, and configurations, and then contact technical support personnel.
5. End.