DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm-143618

Trap Buffer Description

The board temperature exceeded the upper alarm threshold. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=143618, Reason=The fan temperature was too high.)

The board or subcard temperature alarm.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwBrdTempAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.10.13

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813000d

Alarm Name

hwBrdTempAlarm

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.14 hwBrdTempResume-143618

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Indicates the description of the cause of the trap.

EntPhysicalName

Indicates the name of the physical entity, such as "SFU | LPU | MPU slot slotID". The entity name varies according to the board type, such as the SFU, LPU, and MPU.

EntityThresholdType

The abnormal type for temperature.The value can be:

  • 1:high
  • 2:low

EntityThresholdCritical

The warning alarm threshold for warning alarm.

EntityThresholdCurrent

The current value that been measured.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.1

hwEntityThresholdType

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.5

hwEntityThresholdWarning

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.3

hwEntityThresholdCurrent

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

Impact on the System

Temporarily, the services will not be affected. But a speedy solution is needed.

Possible Causes

The fan temperature was too high.

Procedure

1. Check if the filter screen of the fan module is clogged. If the filter screen is clogged, clean the filter screen.

2. Check the ambient temperature. If the ambient temperature is too high, reduce the temperature to a normal level.

3. Check if the fan module is faulty. If there is a fault on the fan module, rectify the fault first.

4. If the ambient temperature is normal but the alarm is still reported, the possible cause is that the module temperature is too high. In this case, collect the information about alarms, logs, and configurations, and then contact technical support personnel.

5. End.