DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid-132618

Trap Buffer Description

The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132618, Reason=Board NP fault.)

The overall function of the board does not take effect.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813002e

Alarm Name

hwBoardInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.6 hwBoardInvalidResume-132618

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the entity such as a chassis.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

  • 1: mpu(1)
  • 2: lpu(2)
  • 3: sfu(3)
  • 4: pic(4)
  • 5: cfcard(5)
  • 6: ofc(6)
  • 7: npu(7)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Services on the board will be affected or even interrupted. This problem must be resolved immediately.

Possible Causes

Board NP fault.

Procedure

1. If the faulty board is neither reset nor powered off, and services on the board are normal, go to Step 4. Otherwise, go to Step 2.

2. Power off the faulty board and then power it on again.

3. If the board cannot be registered or the alarm persists after the board is registered, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.

5. End.