DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.5 hwBoardInvalid-132619

Trap Buffer Description

The board totally failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132619, Reason=The master or slave ACT signal of the MPU board is abnormal.)

The overall function of the board does not take effect.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwBoardInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.5

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x0813002e

Alarm Name

hwBoardInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.6 hwBoardInvalidResume-132619

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the entity such as a chassis.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

  • 1: mpu(1)
  • 2: lpu(2)
  • 3: sfu(3)
  • 4: pic(4)
  • 5: cfcard(5)
  • 6: ofc(6)
  • 7: npu(7)

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Services on the board may be affected and even interrupted. A speedy solution is required.

Possible Causes

The master or slave ACT signal of the MPU board is abnormal.

Procedure

1. Check whether other boards have low-power-related alarms or power-related alarms. If so, handle these alarms first.

2. Remove and reinstall the current standby main control board and check whether the standby main control board is securely installed, whether any bent pins exist, and whether the connectors of the standby main control board are normal. Then, go to Step 4.

3. If the device is reset, remove the other main control board and check whether the main control board is securely installed, whether any bent pins exist, and whether the connectors of the main control board are normal. Then, go to Step 4.

4. If the board is not securely installed, install it securely.

5. If the backplane has bent pins, avoid installing a new board into the faulty slot. Contact technical support.

6. If only the connectors of the board are found to be faulty, replace the board and go to Step 8.

7. If the standby main control board is still not registered or the alarm persists, contact technical support.

8. End.