A power module experienced a partial failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136714, Reason=The current of the power is not average.)
The power supply experienced a partial failure, which may be caused by a component failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwPowerFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.5.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x0813001d |
Alarm Name |
hwPowerFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.4 hwPowerFailResume-136714 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntityTrapFaultID |
To describe the fault id of trap. |
EntPhysicalName |
The textual name of the physical entity. |
Reason |
Reason. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1. If the faulty PM module is newly inserted, check whether it is properly inserted, the backplane has bent pins, or its connector has faults.
2. Execute the operations according to the following conditions.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.