A power module experienced a partial failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136727, Reason=The switch 1 is off.)
The power supply experienced a partial failure, which may be caused by a component failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwPowerFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.5.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x0813001d |
Alarm Name |
hwPowerFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.4 hwPowerFailResume-136727 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntityTrapFaultID |
To describe the fault id of trap. |
EntPhysicalName |
The textual name of the physical entity. |
Reason |
Reason. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1. Check whether switch 1 on the power panel is closed.
2. Close switch 1 and check whether the alarm is cleared.
3. Replace the power module.
Power off the faulty power module before replacing it. Then check whether the alarm is cleared.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.