The fan module failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=139279, Reason=The fan information is abnormal.)
The fan function is disabled.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwFanInvalid |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.6.5 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130017 |
Alarm Name |
hwFanInvalid |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.6.6 hwFanInvalidResume-139279 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntityTrapFaultID |
To describe the fault id of trap. |
EntPhysicalName |
The textual name of the physical entity. |
Reason |
Reason. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1.Change the fan module and check whether the alarm is cleared.
2. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.