DEVM_1.3.6.1.4.1.2011.5.25.219.2.9.2 hwCommunicateResume-140288

Trap Buffer Description

The communication channel resumed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=140288, EntityCommunicateType=[EntityCommunicateType], Reason=The channel monitoring module failed.)

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwCommunicateError

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.9.2

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130011

Alarm Name

hwCommunicateError

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.9.1 hwCommunicateError-140288

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntityTrapFaultID

To describe the fault id of trap.

EntPhysicalName

The textual name of the physical entity.

EntityTrapEntType

The type of this entity.

EntityCommunicateType

The type of this commnuicate.

The value can be:

1. Control channel:1.

2. monitor channel:2.

3. clock channel:3.

4. data channel:4.

Reason

Reason integer.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.4

hwEntityCommunicateType

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

Impact on the System

1.A master/slave board switchover will be performed if the system is installed with two MPUs. On a system with a single MPU, the system will fail to monitor the temperatures or voltages of boards, and the EEPROM will be inaccessible. Services will not be affected temporarily but a speedy solution is required.

2.Traffic between two boards will be affected or event interrupted. Thus, a speedy solution is required.

Possible Causes

The channel monitoring module failed.

Procedure

1.On the system installed with a single MPU, if the alarm persists, collect information about alarms, logs, and configurations, and then contact Huawei technical support personnel.

2.On the system installed with two MPUs, if the alarm persists on both MPUs, collect information about alarms, logs, and configurations, and then contact Huawei technical support personnel.

3.If the slave MPU fails and no master/slave switchover is performed, remove and then install the slave MPU. Then, go to Step 5.

4.If the master MPU fails and a master/slave switchover is performed, remove and then install the current MPU. Then, go to Step 5.

5.If the slave MPU cannot be registered or the failure cannot be rectified, replace the faulty board.

Copyright © Huawei Technologies Co., Ltd.