The communication channel resumed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=140289, EntityCommunicateType=[EntityCommunicateType], Reason=A data channel failed.)
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Critical |
Mnemonic Code |
hwCommunicateError |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.9.2 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130011 |
Alarm Name |
hwCommunicateError |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Clear |
Match trap |
DEVM_1.3.6.1.4.1.2011.5.25.219.2.9.1 hwCommunicateError-140289 |
Parameter | Description |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntityTrapFaultID |
To describe the fault id of trap. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapEntType |
The type of this entity. |
EntityCommunicateType |
The type of this commnuicate. The value can be: 1. Control channel:1. 2. monitor channel:2. 3. clock channel:3. 4. data channel:4. |
Reason |
Reason integer. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.2 |
hwEntityTrapEntType |
- |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.219.1.4 |
hwEntityCommunicateType |
- |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1.A master/slave board switchover will be performed if the system is installed with two MPUs. On a system with a single MPU, the system will fail to monitor the temperatures or voltages of boards, and the EEPROM will be inaccessible. Services will not be affected temporarily but a speedy solution is required.
2.Traffic between two boards will be affected or event interrupted. Thus, a speedy solution is required.
1.Run the display device command in the user view to check the status of the faulty board.
2.Run the display interface command twice in the user view to check whether traffic is being transmitted on the interface of the faulty board.
3.If the alarm persists, collect information about alarms, logs, and configurations, and then contact Huawei technical support personnel.