Board laser shutdown! (IfIndex=[IfIndex] SlotID=[SlotID] CardID=[CardID] PortID=[PortID] InterfaceName=[InterfaceName])
The laser on the port was shut down.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Critical |
Mnemonic Code |
LASER_SHUT |
Trap OID |
1.3.6.1.4.1.2011.5.25.157.2.113 |
MIB |
HUAWEI-PORT-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
IfIndex |
Node ID. |
SlotID |
Slot ID. |
CardID |
Card number. |
PortID |
Port number. |
InterfaceName |
Port name. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.6 |
hwPhysicalPortInSlot |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.7 |
hwPhysicalPortInCard |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.8 |
hwPhysicalPortInPort |
hwPhysicalPortIfIndex |
1.3.6.1.4.1.2011.5.25.157.1.8.1.1.4 |
hwPhysicalPortName |
hwPhysicalPortIfIndex |
1. Run the display laser status command in all views to check the actual laser status.
2. Run the laser turn-on command in the interface view to manually enable the optical module laser. Remove the laser shutdown settings and check whether the fault is rectified.
3. Collect alarm, log, and configuration information and contact technical support engineers.