Nonthreshold Event occured. (IfIndex=[IfIndex], EventLogIndex=[EventLogIndex], EventLogTimestamp=[EventLogTimestamp], EventLogOUI=[TrapLogOUI], EventLogType=[TrapLogType], EventLogLocation=[TrapLogLocation], IfName=[IfName])
Event occurred, such as timeout, link fault, dying gasp, or critical event.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Error |
Mnemonic Code |
ETH_EFM_NON_THRESHOLD |
Trap OID |
1.3.6.1.4.1.2011.5.25.136.1.6.5 |
MIB |
HUAWEI-ETHOAM-MIB |
Alarm ID |
0x00F10002 |
Alarm Name |
NONTHRESHOLDTRAP |
Alarm Type |
communicationsAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
IfIndex |
Index of interface. |
EventLogIndex |
Log sequence. |
EventLogTimestamp |
Time stamp of the event log. |
TrapLogOUI |
OUI of the trap. |
TrapLogType |
The fault type:
|
TrapLogLocation |
Indicates where the event occurs, on the local end or the remote end:
|
IfName |
The name of interface. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.2 |
hwDot3ahEfmEventLogTimestamp |
ifIndex hwDot3ahEfmEventLogIndex |
1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.3 |
hwDot3ahEfmEventLogOui |
ifIndex hwDot3ahEfmEventLogIndex |
1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.4 |
hwDot3ahEfmEventLogType |
ifIndex hwDot3ahEfmEventLogIndex |
1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.5 |
hwDot3ahEfmEventLogLocation |
ifIndex hwDot3ahEfmEventLogIndex |
EFM session failed, services will be interrupted.
Link fault, services will be interrupted.
The remote device restarts, services will be interrupted.
Remote services will be interrupted.
1. Check the value of the EventLogType field in the trap:
2. Run the display this command in the interface view to check whether EFM is enabled on the remote device.
3. Run the display this command in the interface view to check whether the local interface is shut down.
4. Check whether the remote device is being restarted.
5. Check whether a fault occurs on the module associated with EFM.
6. Check whether the physical link is faulty.
7. Restore the module associated with EFM, and then check whether the alarm is cleared.
8. Run the efm enable command in the interface view of the remote device to enable EFM. Then, check whether the alarm is cleared.
9. Run the undo shutdown command in the interface view to check whether the alarm is cleared.
10. After the remote device works normally, check whether the alarm is cleared.
11.Replace the physical link and then check whether the alarm is cleared.
12. Collect alarm information and configuration information, and then contact technical support personnel.
13. End.
The same as Cause 1.
The same as Cause 1.
The same as Cause 1.