The one-way delay of one link in an IPFPM test instance exceeded the upper threshold over five consecutive statistical periods. (TestInstanceId=[InstanceId], AchId=[AchId], IpfpmMcpSeqNoHigh=[SeqNoHigh], IpfpmMcpSeqNoLow=[SeqNoLow], FlowType=[FlowType], SourceDCP=[SrcDcpId], SourceTLP=[SrcTlpId], DestinationDCP=[DstDcpId], DestinationTLP=[DstTlpId], OneDelay=[DelayValue])
The one-way delay of one link in an IP FPM instance exceeded the upper threshold over five consecutive statistical periods.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Error |
Mnemonic Code |
hwIpfpmMultiOneDelayExceed |
Trap OID |
1.3.6.1.4.1.2011.5.25.316.3.10 |
MIB |
HUAWEI-IPFPM-MIB |
Alarm ID |
0x00F100a2 |
Alarm Name |
hwIpfpmMultiOneDelayExceed |
Alarm Type |
qualityOfServiceAlarm |
Raise or Clear |
Raise |
Match trap |
IPFPM_1.3.6.1.4.1.2011.5.25.316.3.11 hwIpfpmMultiOneDelayRecovery |
Parameter | Description |
---|---|
InstanceId |
IP FPM instance ID. |
AchId |
Atomic closed hop ID. |
SeqNoHigh |
32 most significant bits of the statistical period ID. |
SeqNoLow |
32 least significant bits of the statistical period ID. |
FlowType |
Target flow type. |
SrcDcpId |
Source Dcp Id. |
SrcTlpId |
Source Tlp Id. |
DstDcpId |
Destination Dcp Id. |
DstTlpId |
Destination Tlp Id. |
DelayValue |
One-way delay for the target flow. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.316.1.2.7.1.7 |
hwIpfpmMcpOneDelayMulti |
hwIpfpmMcpInstId hwIpfpmMcpAchId hwIpfpmMcpSeqNoHigh hwIpfpmMcpSeqNoLow hwIpfpmMcpOneDelayFlowType hwIpfpmMcpOneDelayMultiSrcDCP hwIpfpmMcpOneDelayMultiSrcTLP hwIpfpmMcpOneDelayMultiDesDCP hwIpfpmMcpOneDelayMultiDesTLP |
1. Check whether abnormal traffic existed on the network when the trap was generated.
2. Check whether the abnormal traffic was caused by misoperations.
3. Delete the misoperation configurations and check whether the trap persists.
4. Check whether the link status was stable when the trap was generated.
5. Check the problem that caused the unstable link status, resolve the problem, and check whether the trap persists.
6. Collect alarm information and configuration information, and then contact technical support personnel.
7. End.