IPFPM_1.3.6.1.4.1.2011.5.25.316.3.7 hwIpfpmDcpFlowConflict

Trap Buffer Description

The flow conflicts with another existing flow.(TestInstanceId=[InstanceId], FlowType=[FlowType], ConflictInstId=[ConflictInstanceId], ConflictFlowType=[ConflictFlowType])

The flow characteristics of a specified target flow in an IP FPM instance conflict with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP.

Trap Attributes

Trap Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwIpfpmDcpFlowConflict

Trap OID

1.3.6.1.4.1.2011.5.25.316.3.7

MIB

HUAWEI-IPFPM-MIB

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Name

This is an event trap and does not involve alarm name.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

-

Trap Buffer Parameters

Parameter Description

InstanceId

IP FPM instance ID.

FlowType

Target flow type.

ConflictInstanceId

IP FPM instance ID in conflict.

ConflictFlowType

Target flow type in conflict.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.316.2.1.8.1.1

hwIpfpmDcpInstId

hwIpfpmDcpInstId

1.3.6.1.4.1.2011.5.25.316.2.1.10.1.1

hwIpfpmDcpFlowType

hwIpfpmDcpInstId

hwIpfpmDcpFlowType

Impact on the System

The performance statistics may be incorrect.

Possible Causes

The flow characteristics of a specified target flow in an IP FPM instance overlap with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP, causing a flow conflict alarm.

Procedure

1. Check whether the flow characteristics of a newly configured target flow in an IP FPM instance overlap with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP.

  • If so, go to Step 2.
  • If not, go to Step 3.

2. Check the cause of the flow characteristics overlap and resolve the problem. Then check whether the alarm persists.

  • If so, go to Step 3.
  • If not, go to Step 4.

3. Collect log information and configuration information, and then contact technical support personnel.

4. End.