L2IF_1.3.6.1.4.1.2011.5.25.42.2.1.7.14 hwSlotMacLimitNumFallingThreshold

Trap Buffer Description

MAC address learning based on SLOT is resumed. (L2IfPort=[L2IfPort], MacLimitVlanId=[MacLimitVlanId], MacLimitVsiName=[MacLimitVsiName], entPhysicalIndex=[entPhysicalIndex], aseTrapSeverity=[aseTrapSeverity], BaseTrapProbableCause=[BaseTrapProbableCause], BaseTrapEventType=[BaseTrapEventType], MacDynAddressLearnNum=[MacDynAddressLearnNum], MacLimitMaxMac=[MacLimitMaxMac], SlotName=[SlotName], DeviceName=[DeviceName])

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwSlotMacLimitNumRaisingThreshold

Trap OID

1.3.6.1.4.1.2011.5.25.42.2.1.7.14

MIB

HUAWEI-L2MAM-MIB

Alarm ID

0x09802017

Alarm Name

hwSlotMacLimitNumRaisingThreshold

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

L2IF_1.3.6.1.4.1.2011.5.25.42.2.1.7.13 hwSlotMacLimitNumRaisingThreshold

Trap Buffer Parameters

Parameter Description

L2IfPort

Interface name.

MacLimitVlanId

VLAN ID.

MacLimitVsiName

VSI name.

entPhysicalIndex

Interface index.

aseTrapSeverity

Alarm severity.

BaseTrapProbableCause

Alarm cause.

BaseTrapEventType

Alarm event type.

MacDynAddressLearnNum

Number of learned dynamic MAC addresses.

MacLimitMaxMac

Maximum number of MAC addresses that can be learned.

SlotName

Board name.

DeviceName

Device name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.4.1.2011.5.25.42.2.1.4.1.10

hwMacDynAddressLearnNum

hwMacLimitPort

hwMacLimitVlanId

hwMacLimitVsiName

1.3.6.1.4.1.2011.5.25.42.2.1.4.1.4

hwMacLimitMaxMac

hwMacLimitPort

hwMacLimitVlanId

hwMacLimitVsiName

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

Impact on the System

The system is not affected.

Possible Causes

The number of MAC addresses learned per slot in the upstream direction fell below the alarm threshold.

Procedure

This trap message is informational only, and no action is required.