LACP_1.3.6.1.4.1.2011.5.25.41.3.4 hwLacpPartialLinkLoss

Trap Buffer Description

Link bandwidth lost partly. (TrunkIndex=[TrunkIndex], TrunkIfIndex=[TrunkIfIndex], TrunkId=[TrunkId], TrunkName=[TrunkName], Reason=[ReasonCode])

Part of the bandwidth of a link was lost.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwLacpPartialLinkLoss

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.4

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x09360002

Alarm Name

hwLacpPartialLinkLoss

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

LACP_1.3.6.1.4.1.2011.5.25.41.3.15 hwLacpPartialLinkLossResume

Trap Buffer Parameters

Parameter Description

TrunkIndex

Index of a trunk

TrunkIfIndex

Index of a trunk interface

TrunkId

ID of a trunk interface

TrunkName

Name of a trunk interface

ReasonCode

Reason why part of the bandwidth of a link was lost or resumed.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.3.3.1.2

hwTrunkIfID

hwTrunkIndex

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

Impact on the System

Part of services were interrupted.

Possible Causes

The number of the Eth-trunk member links that can be selected is smaller than the lower threshold value.

Procedure

1. Run the display interface brief command to check whether the interface is Down.

  • If so, go to Step 2.
  • If not, go to Step 4.

2. Run the undo shutdown command to check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 3.

3. Check whether the physical link is faulty.

  • If so, go to Step 7.
  • If not, go to Step 4.

4. Run the display eth-trunk [ trunk-id [ interface interface-type interface-number | verbose ] ] command to check whether there are member interfaces in the LAG.

  • If so, go to Step 5.
  • If not, go to Step 8.

5. Run the display trunkmembership eth-trunk trunk-id command to check whether the lower threshold for Eth-Trunk member links is set in the LAG; whether the number of Eth-Trunk member links that are successfully negotiated is smaller than the lower threshold for the Eth-Trunk member links that can be Up.

  • If so, go to Step 6.
  • If not, go to Step 9.

6. In the Eth-Trunk interface view, run the least active-linknumber link-number command to correctly set the lower threshold of Trunk member links that can be Up. Then, check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 9.

7. Repair the physical link and then check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 4.

8. Run the eth-trunk trunk-id command in the interface view and add the current Ethernet interface to the Eth-Trunk interface as required. Then, check whether the alarm is cleared.

  • If so, go to Step 10.
  • If not, go to Step 5.

9. Collect alarm information and configuration information, and then contact technical support personnel.

10. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.