LACP_1.3.6.1.4.1.2011.5.25.41.3.3 hwLacpTotalLinkLoss

Trap Buffer Description

Link bandwidth lost totally. (TrunkIndex=[TrunkIndex], TrunkIfIndex=[TrunkIfIndex], TrunkId=[TrunkId], TrunkName=[TrunkName], Reason=[ReasonCode])

All the link bandwidths were lost.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwLacpTotalLinkLoss

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.3

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x09360001

Alarm Name

hwLacpTotalLinkLoss

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

LACP_1.3.6.1.4.1.2011.5.25.41.3.14 hwLacpTotalLinkLossResume

Trap Buffer Parameters

Parameter Description

TrunkIndex

Index of a trunk

TrunkIfIndex

Index of a trunk interface

TrunkId

ID of a trunk interface

TrunkName

Name of a trunk interface

ReasonCode

Reason why all the link bandwidths were lost or resumed.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.3.3.1.2

hwTrunkIfID

hwTrunkIndex

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

Impact on the System

Services are interrupted.

Possible Causes

No link is selected.

Procedure

1. Run the display interface brief command to check whether the interface is Down.

  • If so, go to Step 2.
  • If not, go to Step 4.

2. Run the undo shutdown command to check whether the alarm is cleared.

  • If so, go to Step 8.
  • If not, go to Step 3.

3. Check whether the physical link is faulty.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Run the display eth-trunk [ trunk-id [ interface interface-type interface-number | verbose ] ] command to check whether there are member interfaces in the LAG.

  • If so, go to Step 7.
  • If not, go to Step 6.

5. Repair the physical link and then check whether the alarm is cleared.

  • If so, go to Step 8.
  • If not, go to Step 4.

6. Run the eth-trunk trunk-id command in the interface view and add the current Ethernet interface to the Eth-Trunk interface as required. Then, check whether the alarm is cleared.

  • If so, go to Step 8.
  • If not, go to Step 7.

7. Collect alarm information and configuration information, and then contact technical support personnel.

8. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >