NQA entry over threshold. (OwnerIndex=[OwnerIndex], TestName=[TestName], TargetAddressType=[TargetAddressType], TargetAddress=[TargetAddress], Index=[Index], HopIndex=[HopIndex], AddressType=[AddressType], Address=[Address], Threshold1=[Threshold1], CompletionTimeMax=[CompletionTimeMax], RTDOverThresholds=[RTDOverThresholds])
Indicates that the period of a test exceeded the set threshold. The threshold could be set by the user. The threshold rtd could modify the threshold.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
THRESHOLD_RTD |
Trap OID |
1.3.6.1.4.1.2011.5.25.111.6.4 |
MIB |
NQA-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
OwnerIndex |
Indicates the administrator of an NQA test instance. |
TestName |
Indicates the name of an NQA test instance. |
TargetAddressType |
Indicates the type of the destination address. |
TargetAddress |
Indicates the destination address. |
Index |
Indicates the index of the result table. |
HopIndex |
Indicates the hop index. |
AddressType |
Address type of an NQA test instance. |
Address |
Address of an NQA test instance. |
Threshold1 |
Indicates the RTD threshold of an NQA test instance. |
CompletionTimeMax |
Indicates the maximum RTT value of an NQA test instance. |
RTDOverThresholds |
Indicates the number of times that the RTT exceeds the threshold. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.111.2.2.1.1 |
nqaAdminParaTargetAddressType |
nqaAdminCtrlOwnerIndex nqaAdminCtrlTestName |
1.3.6.1.4.1.2011.5.25.111.2.2.1.2 |
nqaAdminParaTargetAddress |
nqaAdminCtrlOwnerIndex nqaAdminCtrlTestName |
1.3.6.1.4.1.2011.5.25.111.4.1.1.19 |
nqaResultsAddressType |
nqaAdminCtrlOwnerIndex nqaAdminCtrlTestName nqaResultsIndex nqaResultsHopIndex |
1.3.6.1.4.1.2011.5.25.111.4.1.1.20 |
nqaResultsAddress |
nqaAdminCtrlOwnerIndex nqaAdminCtrlTestName nqaResultsIndex nqaResultsHopIndex |
1.3.6.1.4.1.2011.5.25.111.2.1.1.7 |
nqaAdminCtrlThreshold1 |
nqaAdminCtrlOwnerIndex nqaAdminCtrlTestName |
1.3.6.1.4.1.2011.5.25.111.4.1.1.12 |
nqaResultsCompletionTimeMax |
nqaAdminCtrlOwnerIndex nqaAdminCtrlTestName nqaResultsIndex nqaResultsHopIndex |
1.3.6.1.4.1.2011.5.25.111.4.1.1.7 |
nqaResultsRTDOverThresholds |
nqaAdminCtrlOwnerIndex nqaAdminCtrlTestName nqaResultsIndex nqaResultsHopIndex |
1. Run the display cpu-usage command in the system view to check whether the CPU has an excessive load.
2. In the NQA test view, run the display this command to know the current threshold. Then run the threshold rtd command to modify the threshold as required. The recommended value is 20 ms. Perform the test again to check whether the alarm is cleared.
3. Collect alarm information and configuration information, and then contact technical support personnel.
4. End.