PIC_1.3.6.1.4.1.2011.5.25.129.2.5.1 hwPortPhysicalDown-74752

Trap Buffer Description

The status of the physical interface is Down. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[74752], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex],EntPhysicalName=[EntPhysicalName], ReasonDescription=The status of the physical interface is Down.)

Physical state of the port changed to down.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwPortPhysicalDown

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.5.1

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x081300a8

Alarm Name

hwPortPhysicalDown

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PIC_1.3.6.1.4.1.2011.5.25.129.2.5.2 hwPortPhysicalUp-74752

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

To describe the level of trap.

BaseTrapProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

Index of the physical entity.

EntPhysicalName

The textual name of the physical entity.

ReasonDescription

Indicates the description of the possible cause.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.17

hwPortPhysicalDownReason

-

Impact on the System

Traffic forwarding on the physical interface will be affected. Thus, a speedy solution is required.

Possible Causes

The status of the physical interface is Down.

Procedure

1. Check the link between failure port and peer port to make sure the link is normal. Check whether the fault is rectified.

  • If so, go to End.
  • If not, go to Step 2.

2. Run the display interface interface-type interface-number command in the user view to check the status of failure port and peer port.

  • If so, go to End.
  • If not, go to Step 3.

3. If the failure port or peer port is in managing down status, then enter the interface view and run the undo shutdown command, check whether the fault is rectified.

  • If so, go to End.
  • If not, go to Step 4.

4. Collect alarm information, log information and configuration information, and then contact technical support personnel.