PIC_1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail-132142

Trap Buffer Description

The card failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=132142, Reason=The voltage is below the lower alarm threshold.)

The subcard experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwCardFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.3.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130056

Alarm Name

hwCardFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PIC_1.3.6.1.4.1.2011.5.25.219.2.3.4 hwCardFailResume-132142

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity.

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

Services are not affected but this problem must also be resolved in time.

Possible Causes

The voltage is below the lower alarm threshold.

Procedure

1. If the power module fails, first rectify the fault.

2. Run the display voltage slot slot-id command in the user view to check whether the actual voltage exceeds the upper fatal threshold.

3. If the actual voltage exceeds the upper fatal threshold, collect the information about alarms, logs, and configurations, and then contact technical support personnel.