PIC_1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail-135198

Trap Buffer Description

The card failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=135198, Reason=EEPROM is abnormal.)

The subcard experienced a partial failure.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwCardFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.3.3

MIB

HUAWEI-ENTITY-TRAP-MIB

Alarm ID

0x08130056

Alarm Name

hwCardFail

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PIC_1.3.6.1.4.1.2011.5.25.219.2.3.4 hwCardFailResume-135198

Trap Buffer Parameters

Parameter Description

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntityTrapFaultID

Indicates the error code.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity.

Reason

Indicates the description of the cause of the trap.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

-

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

-

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

-

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

-

1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2

hwEntityOperStatus

entPhysicalIndex

Impact on the System

The current services are not affected, but services will be affected after the next startup of the card.

Possible Causes

EEPROM is abnormal.

Procedure

1. Check whether the services on the subcard is running properly.

  • If so, go to Step 4.
  • If not, go to Step 2.

2. Insert the subcard properly,check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 3.

3. Replace the subcard and check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Collect the alarm information, log information, and configuration information, and then contact technical support personnel.

5. End.