QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.20 hwXQoSHardPipeAlarmClear

Trap Buffer Description

The hard-pipe service alarm on interface [interface-name] has cleared.

In VS mode, this trap is supported only by the admin VS.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwXQoSHardPipeAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.32.4.1.11.20

MIB

HUAWEI-XQoS-MIB

Alarm ID

0x00F10039

Alarm Name

hwXQoSHardPipeAlarm

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.19 hwXQoSHardPipeAlarm

Trap Buffer Parameters

Parameter Description

interface-name

Hardpipe interface name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.32.4.1.23.1.1.1

hwXQoSHardPipeAlarmIfIndex

hwXQoSHardPipeAlarmIfIndex

Impact on the System

Services are not affected.

Possible Causes

The hard pipe bandwidth usage fell blew 90%.

Procedure

This trap message is informational only, and no action is required.