QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.61 hwXQoSHardPipeAcBandWthOverAlarm

Trap Buffer Description

The hard pipe configured on the interface [interface-name] over port bandwidth or port shaping.

The AC-side hard pipe bandwidth exceeded the interface bandwidth and became invalid.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwXQoSHardPipeAcBandWthOverAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.32.4.1.11.61

MIB

HUAWEI-XQoS-MIB

Alarm ID

0x00F10171

Alarm Name

hwXQoSHardPipeAcBandWthOverAlarm

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.62 hwXQoSHardPipeAcBandWthOverAlarmClear

Trap Buffer Parameters

Parameter Description

interface-name

Hardpipe interface name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.32.4.1.23.1.1.1

hwXQoSHardPipeAlarmIfIndex

hwXQoSHardPipeAlarmIfIndex

Impact on the System

Packet loss may occur on the hard pipe.

Possible Causes

The hard pipe configured on the interface exceeded port bandwidth or port shaping.

Procedure

1.Run the mpls l2vpn hard-pipe bandwidth bandwidth command in the interface view to decrease the user-side hard pipe bandwidth to a value lower than the interface bandwidth or port shaping value.

Check whether the alarm is cleared.

  • If yes, go to 3.
  • If no, go to 2.

2.Collect alarm information, log information and configuration information, and then contact technical support personnel.

3.End.