QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.62 hwXQoSHardPipeAcBandWthOverAlarmClear

Trap Buffer Description

The hard pipe configured on the interface [interface-name] over port bandwidth or port shaping has cleared.

This alarm is supported only on NetEngine 8000 F1A.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwXQoSHardPipeAcBandWthOverAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.32.4.1.11.62

MIB

HUAWEI-XQoS-MIB

Alarm ID

0x00F10171

Alarm Name

hwXQoSHardPipeAcBandWthOverAlarm

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.61 hwXQoSHardPipeAcBandWthOverAlarm

Trap Buffer Parameters

Parameter Description

interface-name

Hardpipe interface name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.32.4.1.23.1.1.1

hwXQoSHardPipeAlarmIfIndex

hwXQoSHardPipeAlarmIfIndex

Impact on the System

Services are not affected.

Possible Causes

The hard pipe configured on the interface fell below port bandwidth or port shaping.

Procedure

This trap message is informational only, and no action is required.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >