SPM_1.3.6.1.4.1.2011.5.25.19.2.27 hwSysPatchDamagedNotification

Trap Buffer Description

The patch package running on a board was damaged.(PhysicalName=[PhysicalName], PatchName=[PatchName])

A patch package running on a board was damaged.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPatchDamagedAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.19.2.27

MIB

HUAWEI-SYS-MAN-MIB

Alarm ID

0x00F10244

Alarm Name

hwRunningPatchDamaged

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

SPM_1.3.6.1.4.1.2011.5.25.19.2.28 hwSysPatchDamagedClearNotification

Trap Buffer Parameters

Parameter Description

PhysicalName

Name of a physical entity

PatchName

Name of a patch package

VB Parameters

VB OID VB Name VB Index

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.19.1.8.2.1.2

hwPatchFileName

hwPatchFileIndex

Impact on the System

A damaged patch package may cause an LPU or SFU startup failure.

Possible Causes

A patch package running on a board was damaged.

Procedure

1. Run the display device command and check whether the patch package on the slave main control board is damaged.

  • If yes, run the reset slot slot-id command to restart the slave main control board. The patch package can be fixed automatically.
  • If no, go to step 2.

2. Run the display device command and check whether only the patch package on the master main control board is damaged.

  • If yes, run the slave switchover command in the system view to perform a master/slave main control board switchover if conditions permit and services are not affected.
  • If no, go to step 3.

3. If the master/slave switchover cannot be performed or patch packages on both main control boards are damaged, ignore the alarm until the patch package of the next version is loaded using the patch load file-name all run command to clear the alarm.

  • If the alarm persists, go to step 4.

4. Collect alarm information and configuration information, and then contact technical support personnel.