The working mode of the clock source changes. (hwClockChassisId=[hwClockChassisId], hwClockSourceOldLockMode=[hwClockSourceOldLockMode], hwClockAttributeChassisIndex=[hwClockAttributeChassisIndex], hwClockAttributeSysClkLockMode=[hwClockAttributeSysClkLockMode])
The working mode of the system clock source changed.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
hwClkSourceSysClkLockModeChange |
Trap OID |
1.3.6.1.4.1.2011.5.25.186.1.8.2 |
MIB |
HUAWEI-CLOCK-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
hwClockChassisId |
ID of the chassis where the clock source is located. The value is fixed to 1 for a single chassis. |
hwClockSourceOldLockMode |
Running mode of the clock source before the switchover. |
hwClockAttributeChassisIndex |
Index of the chassis where the clock source is located. In the case of a single chassis, the value is fixed to 1. |
hwClockAttributeSysClkLockMode |
Running mode of the system clock. The options are as follows:
|
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.186.1.7.4 |
hwClockChassisId |
- |
1.3.6.1.4.1.2011.5.25.186.1.7.3 |
hwClockSourceOldLockMode |
- |
1.3.6.1.4.1.2011.5.25.186.1.9.1.12 |
hwClockAttributeSysClkLockMode |
hwClockAttributeChassisIndex |
1. Run the display clock config command to check the running mode of the clock source.
2. Run the display clock source command to check whether the clock source is selected.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.