Physical entity is detected failed.(BaseTrapSeverity=16777216, BaseTrapProbableCause=68173, BaseTrapEventType=5, EntityPhysicalIndex=5, EntPhysicalContainedIn=3, EntPhysicalName=TSR_WHOLE frame <chassisID> , RelativeResource=NA, ReasonDescription=<chassisID> does not set fiber length.)
Physical entity is detected failed.
In VS mode, this trap is supported only by the admin VS.
| Trap Attribute | Description | 
|---|---|
| Alarm or Event | Alarm | 
| Trap Severity | Critical | 
| Mnemonic Code | hwEntityCheckFail | 
| Trap OID | 1.3.6.1.4.1.2011.5.25.129.2.1.15 | 
| MIB | HUAWEI-BASE-TRAP-MIB | 
| Alarm ID | 0x0813005d | 
| Alarm Name | hwEntityCheckFail | 
| Alarm Type | equipmentAlarm | 
| Raise or Clear | Raise | 
| Match trap | DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.16 hwEntityCheckResume-68173 | 
| Parameter | Description | 
|---|---|
| BaseTrapSeverity | indicates the severity level of the trap reported to the NMS. | 
| BaseTrapProbableCause | Indicates the possible cause of the trap. | 
| BaseTrapEventType | Indicates the trap type. | 
| EntityPhysicalIndex | Physical index. The physical index varies with the chassis ID. | 
| EntPhysicalContainedIn | Indicates the parent index. | 
| EntPhysicalName | Indicates the name of the entity such as a chassis. | 
| RelativeResource | Indicates the name of the part related to the trap. | 
| ReasonDescription | Indicates the description of the possible cause. | 
| VB OID | VB Name | VB Index | 
|---|---|---|
| 1.3.6.1.4.1.2011.5.25.129.1.1 | hwBaseTrapSeverity | - | 
| 1.3.6.1.4.1.2011.5.25.129.1.2 | hwBaseTrapProbableCause | - | 
| 1.3.6.1.4.1.2011.5.25.129.1.3 | hwBaseTrapEventType | - | 
| 1.3.6.1.2.1.47.1.1.1.1.4 | entPhysicalContainedIn | entPhysicalIndex | 
| 1.3.6.1.2.1.47.1.1.1.1.7 | entPhysicalName | entPhysicalIndex | 
| 1.3.6.1.4.1.2011.5.25.129.1.4 | hwBaseTrapRelativeResource | - | 
| 1.3.6.1.4.1.2011.5.25.129.1.5 | hwBaseTrapReasonDescr | - | 
1.Run the set fiber chassis chassis-id length fiber-length command to configure a correct optical fiber length, and check whether the trap is cleared.
2. Collect the alarm information, log information, and configuration information, and contact technical support personnel.
3. End.