DEVM_1.3.6.1.4.1.2011.5.25.41.4.4 hwIfMonitorSdhErrorResume

Trap Buffer Description

The Sdh error alarm resume.(hwIfMonitorIndex=[hwIfMonitorIndex], hwIfMonitorSdhErrorStatistics=[hwIfMonitorSdhErrorStatistics], hwIfMonitorSdhErrorThreshold=[hwIfMonitorSdhErrorThreshold], hwIfMonitorSdhErrorInterval=[hwIfMonitorSdhErrorInterval], hwIfMonitorName=[hwIfMonitorName])

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwIfMonitorSdhErrorRising

Trap OID

1.3.6.1.4.1.2011.5.25.41.4.4

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x08132134

Alarm Name

hwIfMonitorSdhErrorRising

Alarm Type

processingErrorAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.41.4.3 hwIfMonitorSdhErrorRising

Trap Buffer Parameters

Parameter Description

hwIfMonitorIndex

Index of physical port.

hwIfMonitorSdhErrorStatistics

Sdh error statistics value only for B3.

hwIfMonitorSdhErrorThreshold

Sdh error alarm threshold.

hwIfMonitorSdhErrorInterval

Sdh error alarm interval time(unit is second),only for B3,default value is 10s and 0 is an invalid value.

hwIfMonitorName

Name of physical port.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.5

hwIfMonitorSdhErrorStatistics

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.6

hwIfMonitorSdhErrorThreshold

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.7

hwIfMonitorSdhErrorInterval

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19

hwIfMonitorName

hwIfMonitorIndex

Impact on the System

Services are not affected.

Possible Causes

  • Cause 0: The fault triggering the alarm was rectified.
  • Cause 1: The fault triggering the alarm was rectified.

Procedure

This trap message is informational only, and no action is required.