DEVM_1.3.6.1.4.1.2011.5.25.41.4.6 hwIfMonitorInputRateResume

Trap Buffer Description

Interface input flow bandwidth usage was restored to the trap threshold. (Interface=[IfIndex], BandWidthUsage=[hwIfMonitorInputRatePercentage], TrapThreshold=[hwIfMonitorInputRateThreshold], InterfaceName=[InterfaceName])

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwIfMonitorInputRateRising

Trap OID

1.3.6.1.4.1.2011.5.25.41.4.6

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x081300ae

Alarm Name

hwIfMonitorInputRateRising

Alarm Type

processingErrorAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.41.4.5 hwIfMonitorInputRateRising

Trap Buffer Parameters

Parameter Description

IfIndex

Specifies an interface index.

hwIfMonitorInputRatePercentage

Indicates statistics on incoming traffic.

hwIfMonitorInputRateThreshold

Specifies an alarm threshold for incoming traffic.

InterfaceName

Specifies an interface name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.8

hwIfMonitorInputRate

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.9

hwIfMonitorInputRateThreshold

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19

hwIfMonitorName

hwIfMonitorIndex

Impact on the System

Services are not affected.

Possible Causes

The interface traffic statistics collection period can be configured. The default value is 300s. The average rate of the previous statistics collection period is calculated in every 1/6 of the statistics collection period and then divided by the interface bandwidth to obtain the interface bandwidth usage. If the interface bandwidth usage falls below the interface alarm threshold, the interface rate threshold-crossing alarm is cleared.

Procedure

1. This alarm message is informational only, and no action is required.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.