Alarm only when loop existed in VSI. (VsiName=[vsiname], AlarmReason=[alarmreason], DetectMAC=[detectMAC], InterfaceName1=[AcName1], InterfaceName2=[AcName2], InterfaceName3=[AcName3])
Only an alarm is sent when a loop occurs in a VSI.
| Trap Attribute | Description | 
|---|---|
| Alarm or Event | Event | 
| Trap Severity | Warning | 
| Mnemonic Code | MFLP_VSI_ALARM | 
| Trap OID | 1.3.6.1.4.1.2011.5.25.160.3.8 | 
| MIB | HUAWEI-MFLP-MIB | 
| Alarm ID | This is an event trap and does not involve alarm ID. | 
| Alarm Name | This is an event trap and does not involve alarm name. | 
| Alarm Type | This is an event trap and does not involve alarm type. | 
| Raise or Clear | This is an event trap and does not involve alarm generation or clearance. | 
| Match trap | - | 
| Parameter | Description | 
|---|---|
| vsiname | VSI name. | 
| alarmreason | Causes for the alarm. | 
| detectMAC | MAC address that flaps. | 
| AcName1 | Name of interface 1 on which MAC address flaps. | 
| AcName2 | Name of interface 2 on which MAC address flaps. | 
| AcName3 | Name of interface 3 on which MAC address flaps. | 
| VB OID | VB Name | VB Index | 
|---|---|---|
| 1.3.6.1.4.1.2011.5.25.160.1.2.1.10 | hwMflpVsiCfgAlarmReason | hwMflpVsiName | 
| 1.3.6.1.4.1.2011.5.25.160.1.2.1.14 | hwMflpVsiDetectMAC | hwMflpVsiName | 
| 1.3.6.1.4.1.2011.5.25.160.1.2.1.9 | hwMflpVsiCfgAcName | hwMflpVsiName | 
| 1.3.6.1.4.1.2011.5.25.160.1.2.1.16 | hwMflpVsiCfgAcNameEx1 | hwMflpVsiName | 
| 1.3.6.1.4.1.2011.5.25.160.1.2.1.17 | hwMflpVsiCfgAcNameEx2 | hwMflpVsiName | 
1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the VSI.
2. Run the display loop-detect eth-loop command to check whether Action is displayed as Alarm-only.
3. For the VSI in the alarm, perform either of the following steps:
4. Collect log information and configuration information, and then contact technical support personnel.
1. Run the display current-configuration command to check whether the loopback local command is configured on AC-side interfaces corresponding to the VSI.
2. Collect log information and configuration information, and then contact technical support personnel.