The time source is switched. (hwPtpOldMasterClockId=[hwPtpOldMasterClockId], hwPtpCurrentMasterClockId=[hwPtpCurrentMasterClockId], hwPtpPortIfIndex=[hwPtpPortIfIndex], hwPtpPortOldSourcePortNum=[hwPtpPortOldSourcePortNum], hwPtpPortSourcePortNum=[hwPtpPortSourcePortNum], hwPtpOldPortName=[hwPtpOldPortName], hwPtpPortName=[hwPtpPortName])
The time source is switched.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Event |
Trap Severity |
Warning |
Mnemonic Code |
hwPtpClockSourceChange |
Trap OID |
1.3.6.1.4.1.2011.5.25.187.5.2 |
MIB |
HUAWEI-PTP-MIB |
Alarm ID |
This is an event trap and does not involve alarm ID. |
Alarm Name |
This is an event trap and does not involve alarm name. |
Alarm Type |
This is an event trap and does not involve alarm type. |
Raise or Clear |
This is an event trap and does not involve alarm generation or clearance. |
Match trap |
- |
Parameter | Description |
---|---|
hwPtpOldMasterClockId |
ID of the original master clock. |
hwPtpCurrentMasterClockId |
ID of the current master clock. |
hwPtpPortIfIndex |
Index of the new clock source. |
hwPtpPortOldSourcePortNum |
Port number of the device that provides the synchronization source for the local device. |
hwPtpPortSourcePortNum |
Port number of the device that provides the synchronization source for the local device. |
hwPtpOldPortName |
Name of the port on the device that once provided the synchronization source for the local device. |
hwPtpPortName |
Port name of the device that provides the synchronization source for the local device. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.187.1.14 |
hwPtpOldMasterClockId |
- |
1.3.6.1.4.1.2011.5.25.187.1.32 |
hwPtpCurrentMasterClockId |
- |
1.3.6.1.4.1.2011.5.25.187.2.1.1.47 |
hwPtpPortOldSourcePortNum |
hwPtpPortIfIndex |
1.3.6.1.4.1.2011.5.25.187.2.1.1.30 |
hwPtpPortSourcePortNum |
hwPtpPortIfIndex |
1.3.6.1.4.1.2011.5.25.187.2.1.1.48 |
hwPtpOldPortName |
hwPtpPortIfIndex |
1.3.6.1.4.1.2011.5.25.187.2.1.1.43 |
hwPtpPortName |
hwPtpPortIfIndex |
1. Run the display ptp all command to check whether the interface is in the faulty state.
If yes, the link is faulty or the interface is down. Go to Step 3.
If not, go to Step 2.
2. Run the display this interface and display ptp all config commands to check whether any command is used to change the clock attributes of the interface.
If the clock attribute changes, go to Step 4.
If not, go to Step 3.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.