The value is an integer ranging from 0 to 30000, in milliseconds. The step is 500. For example, the value can be 500, 1000, or 1500.
Views
MA view
Default Level
2: Configuration level
Task Name and Operations
Task Name
Operations
y1731
write
Usage Guidelines
Usage Scenario
If a device detects that a fault alarm is generated without the time specified in the alarm finish time command from clearing alarm reporting, the device immediately reports a fault generation alarm.
If a device detects that a fault alarm is generated within the time specified in the alarm finish time command from clearing alarm reporting, the device reports a fault generation alarm after the time specified in the alarm occur time command elapses.
Prerequisites
An MD and an MA have been configured using the cfm md and ma commands, respectively.
Example
# Set the alarm clearing anti-jitter time to 2000 milliseconds.
<HUAWEI> system-view
[~HUAWEI] cfm enable
[*HUAWEI] cfm md md1
[*HUAWEI-md-md1] ma ma1
[*HUAWEI-md-md1-ma-ma1] alarm finish time 2000