alarm occur time

Function

The alarm occur time command sets an alarm generation anti-jitter time.

The undo alarm occur time command restores the default alarm generation anti-jitter time.

By default, the default alarm generation anti-jitter time is 2500 milliseconds.

Format

alarm occur time time

undo alarm occur time

Parameters

Parameter Description Value
time time

Specifies an alarm generation anti-jitter time.

The value is an integer ranging from 0 to 30000, in milliseconds. The step is 500. For example, the value can be 500, 1000, or 1500.

Views

MA view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
y1731 write

Usage Guidelines

Usage Scenario

  • If a device detects that a fault alarm is generated without the time specified in the alarm finish time command from clearing alarm reporting, the device immediately reports a fault generation alarm.
  • If a device detects that a fault alarm is generated within the time specified in the alarm finish time command from clearing alarm reporting, the device reports a fault generation alarm after the time specified in the alarm occur time command elapses.

Prerequisites

An MD and an MA have been configured using the cfm md and ma commands, respectively.

Example

# Set the alarm generation anti-jitter time to 2000 milliseconds.
<HUAWEI> system-view
[~HUAWEI] cfm enable
[*HUAWEI] cfm md md1
[*HUAWEI-md-md1] ma ma1
[*HUAWEI-md-md1-ma-ma1] alarm occur time 2000
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >